Seitenansicht 4
5
InstallationInstructionsandOwner’sManual
Model # MH40NG/LP
Connect the thermostat wires to gas valve as shown in Figure 4.
THERMOSTAT
Figure 4 connection diagram
9. VENTILATION
a. Theminimumintakeandexhaustairopeningsshallprovide
fornotlessthan400CFMforevery100,000BTUinputexcept
thattheinltrationareamaybeincludedintheintakearea.
b. Wherenatural(gravity)ventilationisprovidedforexhaust,the
openingsmustbedistributedabovetheheaters(preferablyat
thepeakoftheroof)andtheareasofopeningsshallnotbe
less than 300 square inches for every 100,000 BTU input.
10. START-UP PROCEDURE
OPEN THE GAS SUPPLY VALVE OR VALVES.
Figure 5. Thermostate controls
Set the thermostat to the OFF position. See Figure 5. If the
manual gas control knob on the gas valve is not in the OFF
position, partially depress the knob and rotate to the OFF position.
See Figure 6.
Wait 5 minutes to allow gas that may have accumulated in the
mainburnertoescape(especiallyimportantafterinstallation).
Turn the manual gas control knob to the PILOT position.
Depress the manual gas control knob. Using a match, light the
pilotlight.SeeFigure6.Holdtheknobdownforapproximately
30 seconds to allow any air in gas lines to pass through pilot and,
once the pilot is lit, allow the thermocouple to heat up enough to
activate the safety valve in an open position.
POWERPILE GAS VALVE
POWERPILE GENERATOR
MANUAL GAS
CONTROL KNOB
WRENCH
BOSS
GAS INLET
PRESSURE REGULATOR
ADJUSTMENT
STANDARD
PRESSURE
REGULATOR
(Incoming pressure
not exceed 13” W.C.)
PILOT GAS
OUTLET
(PRESSURE
TAPPING
DIRECTLY
BENEATH)
PILOT FLOW
ADJUSTING
SCREW
(BENEATH
COVERSCREW)
PILOTSTAT POWER
UNIT
Figure 6. Gas Valve
Components
Release manual gas control knob and turn to ON. Reset
thermostat to desired temperature.
NOTE:
During the initial startup of MR. HEATER an odor and, perhaps,
some vapor will come from the heater. This is the gasket binding
materialemittingthisodorand/orvapor.Afterapproximately20
minutes this odor will disappear and not occur again.
11. SHUTDOWN
Turn thermostat to OFF.1.
Turn manual gas control knob on gas valve to PILOT position.2.
Partially depress knob and rotate to the OFF position.3.
Close gas supply valves.4.
12. OPERATOR MAINTENANCE
INSTRUCTIONS
1. TROUBLESHOOTING
a. Table4liststhecommonmalfunctionswhichyoumaynd
during the operation or maintenance of your heater.
b. For additional information refer to Honeywell Field Bulletin
enclosed in the heater carton.
c. In the event, results cannot be obtained after performing all
listed solutions, call your Mr. Heater dealer, or the factory
customer service department at 1-800-251-0001.
2. ADJUSTING THE PILOT FLAME
Thepilotameshouldenvelope3/8to½in.(10to13mm)ofthe
tip of the thermocouple or generator. To adjust the pilot flame,
refer to Figure 7.
THERMOCOUPLE
PROPER FLAME ADJUSTMENT
3/8 TO ½ INCH
(10TO13MILLIMETERS)
Figure 7. Proper flame adjustment