Mr. Heater MH40NG Betriebsanleitung Seite 3

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 16
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 2
3
InstallationInstructionsandOwner’sManual
Model # MH40NG/LP
1. GENERAL INFORMATION
a. Your heater comes fully assembled and is tested at the factory
for proper gas and input as stated on the name plate.
b. Before proceeding with the installation, be sure to inspect for
damages.Freightcompanymustbenotiedofanydamages
and request that the inspection be made. MR. HEATER will
send replacement parts for damaged parts only after receiving
a signed inspection report to prove the liability of the freight
company.
c. Do not attempt to operate heater with any other gas than that
indicated on the heater name plate.
d. The installation of heater must conform with local building
codes, or in absence of local codes, with the National Fuel Gas
Code, ANSI Z223.1a/NFPA54, and Standard for Storage and
HandlingofLiqueedPetroleumGases,ANSI/NFPA58.
e. CanadianinstallationsmustcomplywithCAN/CGA-B149.1.2
GasCodewhichcanbepurchasedfromtheCSA(Canadian
StandardsAssociation)website@http://www.csa.caorby
calling 1-800-463-6727.
f. Plugged 1/8” N.P.T. Test Gage Connection is located on the
Heater Gas Valve or a ¼” N.P.T. Connection is located on the
outside of the Cast Venturi.
g. Contact the factory when appliance is to be installed at high
altitudes. Factory supplies high-altitude conversion kits with
instructions and data plates.
For additional information, contact;
MR. HEATER CORPORATION
CUSTOMER SERVICE DEPT.
CLEVELAND, OHIO
1-800-251-0001
*ThefollowingextraNFPAmanualsarehelpfulwheninstalling
MR.HEATERinalocationnotanticipatedinthismanual:
Number Related Subject
NFPA 88 Clearances to Combustible Surfaces
NFPA409 ClearancestoCombustibleSurfaces
DO NOT EXCEED ½ PSI INLET PRESSURE TO HEATER
2. CLEARANCES
Minimumclearancestocombustibles(RefertoTable3).Provide
adequate clearance to combustibles, see Table 3. Also between
control end of heater for servicing and minimum on top and sides
for ventilation and combustion air supply.
Aminimumclearanceof8’aboveoorforpublicgaragesin
accordancewithANSI/NFPANo.409mostrecentedition,orTable
3;thelargerdimensionofANSI/NFPANo.409orTable3istobe
used.
*When selecting installation locations for MR. HEATER ensure that
theopeningofanyexteriororinteriordoorsorwindowswillnot
violate clearances or contact any heater components.
Table 1. BTU Ratings and Supply Pressures
MODEL BTU/HR. RATING GAS SUPPLY PRESSURE (W.C.) ORIFICE
NO. GAS MIN. MAX. MANIFOLD SIZE
NATURAL PROPANE NAT. L.P. NAT. L.P. NAT. L.P. NAT. L.P.
MH/HS40NG 40,000 6.8” W.C. 7” W.C. 5.8” 37
MH/HS40LP 40,000 11” W.C. 14” W.C. 10” 50
Table 2. Heater Dimensions and Orice Sizes
MODEL OPERATING ORIFICE SIZE INPUT SIZE
NO. PRESSURE BURNER PILOT BTU/H WIDTH LENGTH HEIGHT WEIGHT
MH/HS40NG 6.8”w.c. 37 .023 40.000 19-1/4” 30-1/4” 12” 25 lbs.
MH/HS40LP 10”w.c. 50 .015 40,000 19-1/4” 30-1/4” 12” 25 lbs.
Table 3. Installation, Ventilation and Mounting Information
BTU/HR. RATING NORMAL
MODEL GAS MOUNTING CLEARANCES TO COMBUSTIBLE SURFACES
NO. NAT. L.P. POSITION TOP SIDES BACK BELOW
MH/HS40NG 40,000 — HORIZ-30˚ 34” 30” 30” 68”
MH/HS40LP — 40,000 HORIZ-30˚ 34” 30” 30” 68”
Seitenansicht 2
1 2 3 4 5 6 7 8 ... 15 16

Kommentare zu diesen Handbüchern

Keine Kommentare